Duplex Stainless Steel Valves: RFQ and Inspection Checklist
Prepare a duplex stainless steel valve RFQ covering grade, heat treatment, PMI, ferrite, NDE, welding, pressure tests and traceable inspection records.
ZHONGYUE VALVE
11/17/20264 min read


Duplex stainless steel valves are often specified for chloride-bearing, sour, offshore, chemical, and seawater-related duties, but the words “duplex stainless steel” are not a complete purchasing specification. A reliable request for quotation must define the exact grade, service conditions, manufacturing controls, inspection scope, and records required for acceptance.
This guide helps procurement and engineering teams prepare a clear RFQ without assuming that a product photograph proves material grade, corrosion resistance, or compliance.
1. Specify the exact material grade
Start with the project material specification and identify the required casting or forging grade for every pressure-containing part. Common cast duplex grades are listed in ASTM A995 or ASTM A890, including Grade 4A and Grade 5A. Forged components use different ASTM designations and must not be treated as automatically interchangeable.
The RFQ should separately identify the body, bonnet, closure member, stem, seat rings, bolting, and weld overlay where applicable. Avoid descriptions such as “duplex body and trim” unless the project specification clearly defines every included part.
Material questions for the RFQ
Which exact ASTM, ASME, EN, or project material grade is required?
Are cast and forged alternatives permitted?
Which trim and bolting materials are required?
Does the project require NACE MR0175 / ISO 15156 controls for sour service?
Are material substitutions subject to written purchaser approval?
2. Define the process and corrosion basis
Material selection should be reviewed against the actual medium, chloride concentration, temperature, pressure, pH, hydrogen sulfide exposure, solids, velocity, and cleaning chemicals. “Seawater service” alone is not enough because water chemistry, temperature, flow conditions, and shutdown exposure can change the corrosion risk.
The valve manufacturer can quote against the stated specification, but the purchaser or project materials engineer remains responsible for confirming suitability for the process. Do not replace a corrosion review with a general claim that one duplex grade works for every corrosive application.
3. Request heat-treatment evidence
Duplex stainless steels depend on controlled chemistry and heat treatment to develop the intended microstructure. The RFQ should require the applicable solution heat-treatment procedure and traceable records when these are part of the purchase specification.
Records should identify the heat or batch, furnace cycle, temperature range, holding time, and cooling method as required by the governing material standard or project specification. If repair welding is permitted, the purchaser should define whether additional heat treatment or engineering approval is required.
4. Plan PMI and chemistry verification
Positive material identification can help verify alloy identity and reduce material-mix risk. Define which parts require PMI, the inspection stage, sampling rate, instrument method, acceptance criteria, and report format.
Handheld XRF is useful for many alloying elements, but common XRF equipment does not directly measure carbon. If carbon or other light elements are acceptance-critical, specify a suitable method rather than assuming that an XRF report covers the full chemical analysis.
PMI report details
Valve tag, item number, heat number, and component tested
Instrument type and calibration reference
Measured alloying elements and acceptance basis
Test date, inspector identification, and result disposition
5. Define ferrite or phase-balance requirements
Duplex microstructure control may be evaluated by ferrite measurement, metallographic examination, or another project-approved method. The RFQ should state the method, test location, sampling plan, governing document, and agreed acceptance range.
Do not copy a universal ferrite number into every purchase order. Acceptance limits can depend on the material product form, welding procedure, governing standard, project specification, and test method. Any required base-metal, weld-metal, and heat-affected-zone checks should be listed separately.
6. Control welding, repair, and NDE
If fabrication or repair welding is allowed, request qualified WPS and PQR documents, welder qualifications, filler-metal identification, heat-input controls, and repair records as required by the purchase specification. Define whether purchaser approval is needed before pressure-boundary repair.
Nondestructive examination must be tied to a clear extent and acceptance standard. State whether visual, liquid penetrant, magnetic particle, radiographic, or ultrasonic examination applies. Magnetic particle testing may not be appropriate for every duplex component or examination purpose, so the method should follow the material, geometry, and approved procedure.
7. State pressure and functional test requirements
Identify the valve design standard, pressure class, end connection, size, and applicable pressure-test standard. The RFQ should define shell testing, high-pressure closure testing, low-pressure closure testing where applicable, test medium, duration, allowable leakage, and witness or hold points.
For actuated valves, also define operating direction, fail position, actuator supply, stroke time, limit-switch indication, torque or thrust acceptance, and any functional test records required for the assembled unit.
8. Build a traceable inspection-document package
A practical document schedule may include:
Approved drawing and data sheet
Quality plan or inspection and test plan with hold and witness points
EN 10204 3.1 material certificates when specified
Heat-treatment records
PMI and ferrite or phase-balance reports when required
Welding and NDE records applicable to the supplied valve
Dimensional inspection report
Pressure and functional test reports
Coating, marking, preservation, and packing records where applicable
Each report should reference the purchase order, item number, valve tag, heat number, and serial or traceability number used on the supplied product.
Copyable duplex valve RFQ checklist
Valve type, size, pressure class, quantity, and end connection
Design, face-to-face, flange, and test standards
Exact body, bonnet, trim, stem, seat, and bolting grades
Process medium, temperature, pressure, chlorides, pH, and sour-service data
Required heat treatment and traceable records
PMI scope, method, sampling, and acceptance criteria
Ferrite or phase-balance method and project acceptance range
Welding, repair approval, NDE extent, and acceptance standard
Shell, closure, leakage, and functional test requirements
Required EN 10204 certificate type, ITP, reports, and witness points
Tagging, preservation, packing, and final document deadline
Send a technically complete enquiry
For a quotation, send the valve schedule, process data, material specification, inspection requirements, and document list. Review the Zhongyue Valve product range or contact ZHONGYUE VALVE with your project RFQ. The final offer should confirm the exact scope, exceptions, and records included rather than relying on generic material claims.
Zhongyue High Quality Valve Manufacturer
The products are exported to the United States, Europe, the Middle East, Southeast Asia, Russia and other countries and regions, reliable quality and reasonable price. Reliable quality and reasonable price are the basis of our continuous development.
Contact
Get in touch Please leave the questions you need to consult, later we will have a professional technical team to contact you.
Email: sales@hizhongyue.com
Tel: +86 0577-28828932
WhatsApp/WeChat: +86 15658617888
© 2026 ZHONGYUE VALVE. All rights reserved.